- STI “Reset” IP24 Housing
- IP24 Rated
- DIL Switch Addressed
EV-MCP RS RESETSurface Mounting Manual Call Point
Part No. F16N82003
EV-MCP RF RESETFlush Mounting Manual Call Point
Part No. F16N82008
20v-35v
Iquiescent: 200μA
Ialarm: 2.2mA
EN54-11:2001 + A1:2005
RED LED
Operating Voltage
Operating Current
Standard
Alarm Indication
|
| |
| |
- 2 x Input circuits
- 2A@24v Relay Contacts
- Multiple functions selected by DIL switch NOTE: Advanced panel – use C&E software (switch has
no effect)
- DIL Switch Addressed
EV-AIO21 Input/Output Module
Part No. F16S82023
20v-35v
Iquiescent: 200μA
Ialarm: 2.5mA
Ialarm: (From Ext Source) 10mA
EN54-18:2005
RED LED
Operating Voltage
Operating Current
Standard
Alarm Indication
|
| |
| |
- 2 x Input circuits
- Multiple functions selected by DIL switch NOTE: Advanced panel – use C&E software (switch has
no effect)
- DIL Switch Addressed
EV-AIN2 Switch Input Unit
Part No. F16S82024
20v-35v
Iquiescent: 200μA
Ialarm: 2.5mA
EN54-18:2005
RED LED
Operating Voltage
Operating Current
Standard
Alarm Indication
|
| |
| |
- Wall mounted combined sounder/beacon
- DIL Switch Addressed
EV-AV Sounder/Beacon
Part No. F16N82011
20v-35v
Iquiescent: 200μA
Ialarm: (Low O/P) 5mA
Ialarm: (High O/P)10mA
EN54-3:2001 + A1:2002 + A2:2006
and prEN54-23
Operating Voltage
Operating Current
Standard
|
| |
| |
- STI “Reset” IP67 Housing
- IP67 Rated
- DIL Switch Addressed
EV-MCPWP RESET Waterproof Manual Call Point
Part No. F16N82004
20v-35v
Iquiescent: 200μA
Ialarm: 2.2mA
EN54-11:2001 + A1:2005
RED LED
Operating Voltage
Operating Current
Standard
Alarm Indication
|
| |
|
| |
- 2 x Input circuits
- Multiple functions selected by DIL switch NOTE: Advanced panel – use C&E software (switch has
no effect)
- DIL Switch Addressed
- Detector Interface – Std conventional or I.S. conventional
EV-AIN1 Monitor Module
Part No. F16S82025
20v-35v
Iquiescent: Conventional - 600μA
Iquiescent: I.S.- 7mA
Ialarm: Conventional - 10mA
Ialarm: I.S.- 10mA
EN54-18:2005
RED LED
Operating Voltage
Operating Current
Standard
Alarm Indication
|
|
| |
|
- 1 x zone of conventional
sounders / beacons supported
- Requires External PSU
- Module monitors External PSU
for polarity and
Fault O/P
- Module monitors Sounder zone
for Open and Short Circuit Fault
- 1A Fuse
EV-SM Sounder Module
Part No. F16N820213
20v-35v
Iquiescent (loop): 2.68mA
Ialarm (loop): 1.87mA
Ifault - sounder zone s/c (loop): 4.1mA
Ifault - sounder zone o/c (loop): 1.87mA
EN54-18:2005
RED LED
Operating Voltage
Operating Current
Standard
Alarm Indication
|